Hills with trees
Cutting weed
Spare Parts + After-Sales Assistance
5% off
from the 2nd item
The 30-day free return

FIAC ECU 201 - Single-phase, oil-less, portable electric air compressor - 1.5 HP motor - 6 lt.

Questions & Answers (5)
ID: K501306

EAN: 9993089178030

MPN: 1030012000

7,1/10
After-sales assistance & Spare parts
FIAC ECU 201 - Single-phase, oil-less, portable electric air compressor - 1.5 HP motor - 6 lt.
+400 sold
Free gifts from AgriEuro
2 compressor guns2 compressor guns
Spiral hose 5 metresSpiral hose 5 metres
Out of stock
Free Shipping
€ 316,41
Vat included
Technical data
Air compressor tank
6 L
Max. operating pressure
8 bar
Air intake flow
205 L/min
Cylinder head rpm
2850 RPM
Lubrication
Oil-less
Motor type
Induction
Nominal power
1.5 HP
Operating mode
Single-phase 230 V
Manufacturing country
Italy
Product Features
Model
ECU 201
Air compressor type 2
Direct
Air compressor type
Portable
Handheld
yes
Operating mode
Single-phase 230 V
Max. operating pressure
8 bar
Number of tanks
2
Tank capacity
6 L
Air compressor tank
6 L
Noise level
97 LwA
Manufacturing country
Italy
Motor data
Motor type
Induction
Nominal power
1.5 HP
Air compressors engine speed
2850
Power supply
220 V electric
Pump data
Air intake flow
205 L/min
Lubrication
Oil-less
No. of cylinders
1
Cooling manifold
No
Manufacturing country
Italy
Transmission data
Transmission type
Coaxial type direct
Cylinder head rpm
2850 RPM
Equipment
No. of outlet couplings
1
Front handle
Yes
Pressure regulator with condensate filter
No
Double tank
yes
Free gifts/extra features
Instructions manual
Yes
Dimensions and logistics
Product dimensions in cm (L x W x H)
40 x 21 x 44 cm
Net weight
17 Kg
Packaging
Original packaging
Assembly time
Assembled

Add Accessories and get a discount
You're viewing:
Customers also viewed:
Description

Fiac ECU 201 Electric Air Compressor

The ECU 201 air compressor is ideal for use with portable compressed air tools. The very small size makes it easy to transport in a car or any other vehicle, especially suitable for those who daily use the equipment for work.

Its low rpm rate, 2850 rpm, allows it to last twice as long as the average air compressors (2800 rpm) It has a FIAC F 205 pumping unit.

FIAC is a multinational company born in Italy with production sites all over the world. It is a market leader in the production of air compressors.

Equipped with an electric induction motor with a power of 1.5 Hp. It is equipped with two tanks of 3 L each. It features a compressed air suction capacity of 205 L/min and an air pressure of 8 bar, it also allows for a fast air cooling.

It weights only 17 Kg and, thanks to the side handle, it is possible to easily carry the compressor everywhere.

In addition, being equipped with an oilless motor (no oil needed), maintenance operations are also reduced and there is no risk of oil leakage even when the air compressor is placed in a horizontal position.

Technical features

The moving components feature innovative constructive solutions, with a low friction coefficient and high wear resistance materials. Therefore, no lubrication is required during use, thus guaranteeing a high reliability and a compressed air completely free of oil residues.


Air intake flow: 205 L/min

Pumping unit type: coaxial oil-free
- no lubrication
- no maintenance

Pressure: 8 bar

Electric motor power: 1.5 Hp

Tank: 6 lt

Dimensions:
- Length: 400 mm
- Height: 440 mm
- Width: 210 mm

Weight: 17 kg

Controls

The FIAC ECU 201 air compressor features easy and user-friendly controls, which are divided into:

Output air pressure gauge

Tank air pressure gauge

Power switch

Female outlet fitting

Pressure adjusting knob

Other features

Schuko plug

Ergonomic lifting handle

Anti-vibration rubber pads for greater stability

Condensate drain valve

Recommendations for use - Electric Air Compressors

Recommendations for use

To ensure maximum durability and efficiency of the machine, the following instructions must be strictly observed. Failure to do so constitutes improper use, with a serious risk of damage to the product (such damage is not covered by the warranty).

  • Tank maintenance and condensate drainage: Moisture contained in the intake air accumulates as condensate at the bottom of the tank, due to the thermal processes generated during compression. Drain the condensate after each use by operating the lower drain valve, turning it carefully to avoid sudden discharges of compressed air and liquid. Failure to carry out this maintenance task may lead to internal corrosion of the tank. Furthermore, condensate accumulation reduces the effective air volume, causing abnormal motor restart cycles and the transfer of impurities to connected tools, with the resulting risk of premature damage to the entire system.
  • Suitability of extension leads: Do not use unsuitable extension leads. Given the  high motor power, it is essential to ensure a constant power supply. Undersized cabling causes voltage drops that prevent the motor from reaching the correct speed, leading to abnormal overheating and permanent damage to electrical components. Use only cables with a minimum cross-section of 2.5 mm². This cross-section is necessary to handle the high current absorption, especially during start-up.

Unwind the extension lead completely before use. Never use the machine if the power cable is partially coiled or bunched up. Heat build-up due to induction can melt the cable and cause serious electrical damage to the motor or a fire hazard.

  • Operating position:  The air compressor must only be installed in environments free from humidity, preferably in dry locations that are fully protected from weather exposure and potential water splashes. Adequate ventilation must be ensured by maintaining a clearance of at least 50 cm between the machine and any wall or obstacle, in order to allow for proper air circulation and effective heat dissipation. The installation area must also guarantee a high level of air cleanliness and be free from dust, fumes, chemical vapours, or flammable gases. Failure to comply with these requirements exposes the product to the following risks:
  1. Critical overheating: insufficient ventilation or installation in confined spaces impairs the cooling of the motor and pump assembly, resulting in reduced service life.
  2. Safety risks: the presence of volatile or flammable substances may compromise the structural integrity of the machine or the safety of the operator.

 

  • Obstruction of cooling and ventilation systems:  During machine operation, the air compressor must not be covered with sheets, boxes or makeshift casings, as such barriers prevent the air flow required for cooling the internal components. Blocking the ventilation slots causes a rapid rise in operating temperature, with the consequent risk of irreversible damage to the motor and the seals of the pumping unit. If protective covers are used during periods of inactivity, these must be completely removed before any start-up attempt to ensure the full efficiency of the heat dissipation system, thus preventing critical overheating.
  • Power supply and connections suitability: The air compressor must be connected exclusively to an electrical socket rated for the motor’s nominal power. Avoid using unsuitable sockets or connections located too far from the main electrical system. Failure to comply with these requirements exposes the machine to insufficient voltage conditions, seriously compromising the start-up phase, causing start-up difficulties, abnormal stresses and the sudden tripping of protective devices (circuit breakers or residual-current devices).
  • Shutdown procedure and static pressure management: It is recommended not to leave the tank pressurised during periods of inactivity. After switching off (OFF position), the residual pressure must be released and the drain valve opened, leaving the tank empty in order to promote the evaporation of internal moisture. Maintaining constant pressure, in fact, promotes condensation build-up and accelerates the deterioration of pneumatic components, such as diaphragms and valves, drastically reducing the overall reliability of the system and its operational life.
  • Checking the oil level: Before each use, check the oil level in the pumping unit. The level must fall within the range indicated by the oil level indicator or the dipstick, if fitted. Do not operate the air compressor if the oil level is too low, too high or if the oil is contaminated. An insufficient oil level can cause overheating, accelerated wear, seizure of the pumping unit and damage not covered by the warranty. An excessive oil level can cause leaks, oil leakage and oil carry-over into the compressed air circuit.

Operating position: Use the air compressor exclusively in a vertical position, on a flat and stable surface. Use on sloping surfaces may compromise the correct lubrication of the pumping unit.

Free items & Standard equipment

COMPLIMENTARY: GeoTech accessories kit for air compressors - 3 tools

This extensive air compressor accessories kit includes:

- Tyre inflating gun with
integrated pressure gauge

- Air blowing gun

- Coiled air hose

Standard equipment

The air compressor is shipped in its original packaging.

Instructions manual included.

Feedback & Reviews
5,00
5,00
5,00
5,00
5,00
5,00
5,00
All customers' pictures
All customers' video
Ordina per:
Ordina per:
Ordina per:
Filtra le recensioni che citano:
Questions & Answers