Hills with trees
Cutting weed
Spare Parts + After-Sales Assistance
5% off
from the 2nd item
The 30-day free return

Master DC 61 Hybrid - Direct Heating Diesel-fuelled Hot Air Generator

Add a question
ID: K601470

EAN: 8053670893788

MPN: 4.011.200

8,0/10
After-sales assistance & Spare parts
Master DC 61 Hybrid - Direct Heating Diesel-fuelled Hot Air Generator
FREE
Tarpaulin cover and storageTarpaulin cover and storage
Power supply
Diesel-powered
Max. heat output
17 kW
Body material
Enamelled steel
Starting mode
Electric
Manufacturing country
Italy
Product Features
Model:
DC 61 Hybrid
Power supply:
Diesel-powered
Body material:
Enamelled steel
Type:
Direct
Handheld:
Operating mode:
Electric 230 V
Start:
manual
Max. heat output:
17 kW
Nominal heat output:
10-16 kW
Power Btu/h:
37.500 - 75.000 approx.
Power Kcal/h:
15.500 - 28.500 approx.
Absorption:
1 A
Tank capacity:
11 L
Thermostat:
Optional
Fuel consumption:
1.6 kg/h
Starting mode:
Electric
Recommended for open spaces:
Yes
Recommended for ventilated areas:
Yes
Manufacturing country:
Italy
Equipment
Thermal-protected motor:
Yes
Over-heating thermostat:
Yes
Electronic flame sensor with photocell:
Yes
Stainless steel combustion chamber:
Yes
Tank level indicator:
yes
Free gifts/extra features
Fuel filter:
Yes
Instructions manual:
Yes
Dimensions and logistics
Product dimensions in cm (L x W x H):
56X34,5X57,5
Net weight:
19 Kg
Packaging:
Original packaging
Original packaging/s dimensions in cm (L x W x H):
68x38x53 cm
Gross weight (packaging included) :
21 Kg
Assembly time:
Assembled
Arriving on 15/04/25
Free Shipping
Estimated delivery: 24/04/2025 - 28/04/2025
€ 1.340,76
Vat included

You're viewing:
Customers also viewed:
Description

Master DC 61 Hybrid diesel-fired hot air generator

Master DC 61 Hybrid infrared diesel-fired hot air generator

Master DC 61 is the brand new diesel heater that can be powered by a lithium-ion battery. It can also be powered at 230 volts via the included adapter.

Professional design.

Thanks to its weight and small size, it can be easily transported and capable of heating any environment.

It is equipped with a diesel indicator to check the level of diesel in the heater and a socket for analogue or digital remote thermostat.

Ultra-safe 14V Lithium-ion battery, with 4 hours autonomy and very low recharge time, only 60 minutes for a full charge.

The hot air generators are equipped with safety devices for preventing the risk of overheating, an electronic flame control with photocell and anti-tilting sensors.

Master guarantees a 3-year warranty!

Master DC 61 includes a lithium-ion battery and a converter, but can be also powered through classic power socket.

Stainless steel combustion chamber.

Hot air generators are ideal for heating large spaces that are difficult to heat with traditional systems such as workshops, building sites, greenhouses, garages, livestock farms and much more.

Main features

  • Highly silent
  • Radiant heating
  • No air displacement
  • Electronic flame control with photocell
  • Post-ventilation system
  • Fuel quantity indicator
  • Possible room thermostat connection
  • Pump filter, suction filter and inlet filter
  • Possibility of adjusting the heat direction (tiltable)
  • Cart included

Focus on the handle

Focus on the controls

Focus on the wheels

Focus on the fuel tank level indicator

The types of fuels that can be used include:

  • Diesel
  • Transport diesel
  • Agricultural diesel
  • Heating oil
  • Kerosene

How to select the ideal hot air generator according to your needs

Important features that the operator has to consider in order to choose the ideal gas heater which best suits his requirements according to the room that has to be heated up:

  • Dimensions of the area that has to be heated up [V]
  • The ideal temperature [ΔT ] that has to be reached
  • Room thermal insulation [K]

High thermal insulation: k = 1

Medium levels thermal insulation: k = 2

Low levels thermal insulation: k = 3

No thermal insulation: k = 4

Therefore, the heat requirements can be also calculated by using the following formula:

V x ΔT x K [kcal/h]

For example:

V = width 4 m width, 12 m length, 3 m height, room volume = 144 m³

ΔT = outdoor temperature -5ºC, room required temperature +18ºC, room temperature = 23ºC

K = 4 not-insulated room

The formula above mentioned brings to the following result: 144 x 23 x 4 = 13 248 kcal / h, which has to be compared with the data written on the machine serial no. plate, which highlights this heater functionality being able to produce larger volumes of instant heat compared to that one needed.

Converting to kW is easy, just multiply the result by 0.001163, so 13248 x 0.001163 = 15.4 KW

Free items & Standard equipment

COMPLIMENTARY: Heavy-duty cover for covering and storage

Essential to protect your generator when is not in use.

This cover is fast and easy to place: in just a few seconds your machinery is protected from dust and humidity.

Specifically designed to perfectly fit small machines.

Easy to fold and store thanks to its small overall size!

Free items inlcuded

The hot air generator is shipped shipped its original packaging on pallet.

The packaging includes:

  • Operation and maintenance instructions
  • Battery and charger
Feedback & Reviews
5,00
5,00
5,00
5,00
5,00
5,00
5,00
All customers' pictures
All customers' video
Ordina per:
Ordina per:
Ordina per:
Filtra le recensioni che citano:
Questions & Answers